Power Solutions |
|
|
ON-SAFE Series |
Server / Rackmount Systems |
|
|
CPO-S2000
· High Frequency Technology
· Space - minimized Design
· Simple Installation and Operation
· High Reliability
· Cost Efficent
|
|
|
|
|
|
CAPACITY |
VA/W |
2000VA / 1400W |
INPUT |
Voltage Range |
Acceptable Voltage Range |
Base on load percentage (100%-80% / 80%-70% / 70%-60% / 60%-0%) |
Line Low Transfer |
160VAC/140VAC/120VAC/110VAC± 5VAC |
Line Low Comeback |
175VAC± 5VAC |
Line High Transfer |
300VAC± 5VAC |
Line High Comeback |
285VAC± 5VAC |
|
Phase |
Single phase with ground |
|
OUTPUT |
Voltage |
220VAC/230VAC/240VAC |
Frequency Regulation (Batt. Mode) |
50 ± 0.2 Hz |
Harmonic Distortion |
≦4% THD ( Linear Load) ≦7% THD ( Non-Linear Load) |
Output Waveform (Batt. Mode) |
Pure Sinewave |
|
TRANSFER TIME |
Typical |
Zero (AC to DC); 2.5ms (Inverter to Bypass Typical ) |
BATTERY |
Battery Capacity & Quantities |
12V/7.2Ah x 8 pcs |
Recharging Time |
5 hours to 90% |
Backup Time (at a full load) |
>9 minutes |
Charging Current (Max.) |
1.0A |
Charging Voltage |
110Vdc ± 0.4V |
|
ENVIRONMENT |
Operation Temperature |
0-40°C |
Operation Humidity |
20-90% (NON-CONDENSING) |
Audible noise |
<50dB @ 1 Meter |
|
INTERFACE |
Smart RS-232 |
Software supports Windows 98/NT/2000/XP/2003/ME,
Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC |
SNMP Option |
Power management from SNMP manager and web browser |
|
|
|
........................................................................................................................................................................................................... |
|
|
|
|
|
|